PS11 CAPABLE FORWARD SCATTER PARTICULATE CEM
PCME STACK 181
US EPA PS11 compliant ProScatter™ particulate CEM providing high quality emission measurement for low dust concentrations from industrial processes
Utilising the patented ProScatterTM Forward Scatter measurement technique for measuring particulate concentration levels, typically between 0.06 mg/m3 to 300 mg/m3, this measurement technique offers improved levels of performance which make the PCME STACK 181 very suitable for use as a PM CPMS or PM CEMS that need to comply with US EPA PS-11 for Site Operators looking to satisfy the recent MACT and MATS rules.
The PCME STACK 181 is suitable for measuring particle emissions after both bag filter and electrostatic precipitator arrestment plant.
- Robust design with no critical moving parts
- Available for use in high-temperature stack conditions and Ex hazardous zones
- Easy to fit multi-patterned flange
- Adjustable monitoring depth to ensure sampling in the most representative part of the flow path
- For use as PM-CPMS or PM-CEMS that need to comply with PS-11
- ProScatter® technology offers enhanced measurement due to reduced cross-sensitivity of particle type and size
- Features automatic zero and upscale checks that fully challenge the system’s ability to measure forward-scattered light and satisfy daily drift checks
- Easily audited with manual filters
- Stacks after bag filters, cartridge filters, cyclones, electrostatic precipitators, no filtration.
- Non-condensing / dry flue gases
Typical Applications:
- Incineration
- Metals eg Steel/Aluminium
- Minerals eg Cement/Gypsum
- Chemicals eg TiO2 / Refinery
- Power Generation Plant eg Coal/Biomass
TECHNICAL SPECIFICATIONS | |
Measured parameters | Dust |
Technology | ProScatterTM Forward Scatter |
Measurement/Monitoring capability | 0-200 mg/m³* |
Stack/Duct diameter suitability | up to 8m |
Flue gas temperature | up to 500°C |
Baghouse | YES |
Cartridge Filter | YES |
Ceramic Filter | YES |
Coalescent Filter | YES |
Cyclone | YES |
Electrostatic Precipitator (ESP) | YES |
Wet Electrostatic Precipitator (WESP) | / |
Wet Scrubber | / |
Sensor variants | Stainless Steel |
QA checks | YES |
* Application dependant
TECHNICAL DATA | |
Measurement capability | 0 – 1000 mg/m3 |
Certification Range | 0 – 15 mg/m3 0 – 100 mg/m3 |
Resolution | 0.01 mg/m3 |
Sensor Variants | Stainless Steel (standard). Corrosion resistant Hastelloy (option) |
Stack Temperature Ranges | 0-250°C. Up to 500°C option |
Functionality and QA Checks | Automatic zero and upscale checks QA data logging |
Data Outputs | RS485 (Modbus) output to Controller |
Air Purge | requires continuous air purge |
Enclosure Protection Rating | IP66 |
- US EPA PS-11 compliant
- Ex Zone 2