ELECTRODYNAMIC® APPROVED PARTICULATE CEM
PCME STACK 980
MCERTS EN 15859 Filter Dust Approved Particulate monitoring system providing high quality emission measurement for low dust concentrations from dry industrial processes including Baghouses and Cartridge Filters
- Robust design unaffected by product build-up on the sensor rod
- No additional services such as air purge required, providing lower cost of ownership
- Simple maintenance no requirement for specialist service personnel
- Networking up to 16 sensor channels via Modbus and providing multiple inputs and outputs for external connections
- Extensively used for measurement (mg/m³) and leak location in bag filter stack applications
- Advanced sensor design includes drift checks (zero and span) and contamination checks
- Passive/Active and fully insulated sensor options available for applications with stack condensation and damp particulate prevents potential short circuit to stack wall
- Stacks after bag filters, cartridge filters, cyclones, electrostatic precipitators, no filtration
- Non-condensing / dry flue gases
- Variable velocities within range 8 – 20 m/s (typical bag filter velocity ranges), constant velocity required outside this range
- After process dryers
Typical Applications:
- Incineration
- Metals (eg Steel/Aluminium)
- Minerals (eg Cement/Gypsum)
- Chemicals (eg Detergent / Carbon Black)
- Power Generation Plant (eg Coal/Biomass)
TECHNICAL SPECIFICATIONS | |
Measured parameters | Dust |
Technology | ElectroDynamic® Advanced Probe Electrification |
Measurement/Monitoring capability | 0-1000 mg/m³* |
Stack/Duct diameter suitability | up to 8m |
Flue gas temperature | up to 800°C |
Baghouse | YES |
Cartridge Filter | YES |
Ceramic Filter | YES |
Coalescent Filter | YES |
Cyclone | YES |
Electrostatic Precipitator (ESP) | / |
Wet Electrostatic Precipitator (WESP) | / |
Wet Scrubber | / |
Sensor variants | Stainless Steel Fully insulted PTFE coated Passive/Active |
QA checks | YES |
* Application dependant
TECHNICAL DATA | |
Measurement capability | 0 – 1000 mg/m33 |
Sensor Variants | 316 Stainless Steel / Fully insulated PTFE coated (option) / Passive/Active (option) |
Stack Temperature Ranges | 0 -250°C up to 800°C (option) |
Functionality and QA Checks | Automatic zero and span / Short circuit check / Contamination check / Drift checks |
Data Output | RS485 (Modbus) output to Controller |
Air Purge | option |
Enclosure Protection Rating | IP66 |
- MCERTs certified to EN15859 (Filter Dust monitor)
- EX Zone 2, 20
- US EPA MACT Compliant BLD