QAL1 Forward Scatter Particulate CEM

QAL1 FORWARD SCATTER PARTICULATE CEM

PCME QAL 181

 

QAL1 Approved ProScatter™ particulate CEM providing high quality emission measurement of low dust concentrations from dry industrial processes

3 QAL1 certified ranges, including 0 – 7.5 mg/m3, the lowest achievable for any PM-CEM
  • Robust design with no critical moving parts
  • Available for use in high-temperature stack conditions and Ex hazardous zones
  • Easy to fit multi-patterned flange
  • Adjustable monitoring depth to ensure sampling in the most representative part of the flow path
  • Enhanced measurement due to reduced cross sensitivity to particle type and size
  • ProScatter® technology offers enhanced measurement due to reduced cross-sensitivity of particle type and size
  • Easily audited with manual filters
  • Stack Particulate monitoring after bag filters, cartridge filters, cyclones, electrostatic precipitators, no filtration
  • Non-condensing / dry flue gases

Typical Applications Include:

  • Incineration
  • Metals (eg Steel/Aluminium)
  • Minerals (eg Cement/Gypsum)
  • Chemicals (eg TiO2 / Refinery)
  • Power Generation Plant (eg Coal/Biomass)
TECHNICAL SPECIFICATIONS
Measured parameters Dust
Technology ProScatterTM Forward Scatter
Measurement/Monitoring capability 0-1000 mg/m³*
Stack/Duct diameter suitability up to 8m
Flue gas temperature up to 500°C
Baghouse YES
Cartridge Filter YES
Ceramic Filter YES
Coalescent Filter YES
Cyclone YES
Electrostatic Precipitator (ESP) YES
Wet Electrostatic Precipitator (WESP) /
Wet Scrubber /
MCERTS & TÜV (UBA) to EN15267-3 YES
QAL1 certified to EN14181 YES
QAL3 to EN14181 YES
GOST YES
ATEX YES
Sensor variants Stainless Steel
Hastelloy® corrosion resistant
QA checks YES

* Application dependant

TECHNICAL DATA
Measurement capability 0 – 1000 mg/m3
Certification Range 0 – 7.5 mg/m3
0 – 15 mg/m3
0 – 100 mg/m3
Resolution 0.01 mg/m3
Sensor Variants Stainless Steel (standard). Corrosion resistant Hastelloy (option)
Stack Temperature Ranges 0-250°C. Up to 500°C option
Functionality and QA Checks Automatic zero and upscale checks QA data logging
Data Output RS485 (Modbus) output to Controller
Air Purge requires continuous air purge
Enclosure Protection Rating IP66
  • MCERTs and TÜV (UBA) certified to EN15267-3 (incl. 0-7.5 mg/m3)
  • QAL1 as defined by EN14181
  • QAL3 compliance to EN14181
  • GOST / EAC Approved
  • Ex Zone 2